Fault Code Lookup

HVAC Sales Master
2 blinks
Pressure switch circuit open
This code typically points to
  • Inducer draft insufficient
  • Blocked pressure-switch tubing or inducer port
  • Blocked or restricted vent
  • Blocked heat exchanger
  • Intermittent pressure-switch operation
  • Water/moisture in hoses

Next checks to confirm
  1. Check negative pressure with Magnehelic
  2. Inspect pressure-switch tube/port
  3. Inspect venting
  4. Inspect hoses and switch contacts
  5. Inspect heat exchanger restriction if indicated

Escalation
Fault indication; on related later boards, prolonged proving failure becomes timed soft lockout
Reset behavior
Clears when pressure-switch circuit proves normally.
Urgent
Fix now
Source
Rheem Gas Furnace FAQ flash-code meanings and causes; value-line installation troubleshooting chart