Fault Code Lookup

HVAC Sales Master
Green ON / Red FLASH
Pressure switch closed fault (stuck closed when inducer is off)
This code typically points to
  • Pressure switch contacts stuck closed
  • Water/condensate in pressure tubing causing false closed reading
  • Inducer relay held on unexpectedly
  • Wiring short in pressure-switch circuit

Next checks to confirm
  1. Verify pressure switch is open at rest before inducer starts
  2. Inspect pressure-switch tubing/port for water, blockage, or kinks
  3. Verify inducer is not being energized out of sequence and switch circuit is not shorted

Escalation
If switch is mechanically open and wiring is normal but board still reads closed, the fault shifts toward board input or relay/control sequencing.
Reset behavior
Clears when startup proofing sequence sees the switch open when expected.
Urgent
Fix now
Source
Nordyne/UTEC wiring-diagram fault table (FG7SA installation manual)