437 / Inverter Flash 65
OD Inverter Heat-Sink Temperature Sensor Fault
This code typically points to
  • Heat-sink sensor reading below 4°F or above 264°F after 10 minutes of operation

Next checks to confirm
  1. Check sensor condition and outdoor inverter section

Escalation
Outdoor unit stops compressor and fan
Reset behavior
Service-soon condition auto clears when inverter sends clear message; service-urgent condition clears by disconnecting and reconnecting outdoor power.
Urgent
Fix now
Need deeper detail?
Retrieve the subcode for this platform:
  1. On thermostat: Menu > Settings > Advanced Settings > Dealer Control Center > Notifications
  2. Review active alarms on homeowner notification screen or in Dealer Control Center > Notifications
  3. For service-app access, press the smart hub commissioning button once
  4. Connect the mobile device to the smart hub when the LED begins blinking green
  5. Use the app as a service tool after system commissioning is already complete (S30 service session auto-logs out after 30 minutes)
Tool required: iComfort Mobile Setup application for service workflow
Source
Residential Communicating Systems Alert Code Guide, p.40