Fault Code Lookup

HVAC Sales Master
432 / Inverter Flash 28
OD Inverter DC Link High Voltage
This code typically points to
  • DC link capacitor voltage too high; guide states greater than 480 VDC

Next checks to confirm
  1. Check U/V/W wiring
  2. Check compressor winding resistance

Escalation
Outdoor unit stops; anti-short-cycle starts; if repeated 10 times in 60 consecutive minutes, system locks out to service urgent
Reset behavior
Disconnect power to outdoor unit and restart.
Urgent
Fix now
Need deeper detail?
Retrieve the subcode for this platform:
  1. On thermostat: Menu > Settings > Advanced Settings > Dealer Control Center > Notifications
  2. Review active alarms on homeowner notification screen or in Dealer Control Center > Notifications
  3. For service-app access, press the smart hub commissioning button once
  4. Connect the mobile device to the smart hub when the LED begins blinking green
  5. Use the app as a service tool after system commissioning is already complete (S30 service session auto-logs out after 30 minutes)
Tool required: iComfort Mobile Setup application for service workflow
Source
Residential Communicating Systems Alert Code Guide, p.36