Check Furnace
Thermostat scroll message indicating the connected furnace has an active fault requiring service lookup at equipment level
This code typically points to
  • Mirrors active furnace faults such as E0 through E9, d0, d4, b0 through b3, b7, b9

Next checks to confirm
  1. Note thermostat message
  2. Go to furnace board dual 7-segment display
  3. Read exact equipment code
  4. Troubleshoot from furnace manual

Escalation
Service-call state while active equipment fault is present
Reset behavior
Clears when the underlying furnace fault clears.
Urgent
Fix now
Need deeper detail?
Retrieve the subcode for this platform:
  1. For Daikin One+ thermostat: Enter commissioning/advanced menus
  2. Daikin One+: Go to Step 4: System Optimization > Error History
  3. Daikin One+: Review each logged error by date/time, code-equipment pairing, and description
  4. Daikin One+: Where supported, review the minor error code field
  5. Daikin One+: Use Clear Error History when needed
  6. For Goodman ComfortNet board (no Daikin thermostat): From the status menu, depress the right push button once
  7. Goodman ComfortNet: Use left or right button to review fault history
  8. Goodman ComfortNet board: recall last 6 faults from fault-history menu
Source
DC96VC/DM96VC Service Instructions troubleshooting chart, multiple entries on pp.45-48