E9
High-stage pressure-switch circuit is not closed; furnace operates in low stage only
This code typically points to
  • Pressure-switch hose blocked/pinched/improperly connected
  • Blocked flue/inlet air pipe
  • Blocked drain
  • Weak induced-draft blower
  • Incorrect pressure-switch set point or malfunctioning contacts
  • Loose/improper wiring

Next checks to confirm
  1. Inspect hose and venting/intake/drain
  2. Verify induced-draft performance
  3. Correct pressure-switch set point/contact issue
  4. Tighten/correct wiring

Escalation
Furnace fails to operate on high stage and remains in low stage only
Reset behavior
Clears after high-stage pressure-switch proving is restored.
Service Soon
Schedule repair
Source
DC96VC/DM96VC Service Instructions troubleshooting chart, p.47