b6
Over/under-voltage trip or over-temperature trip on blower motor
This code typically points to
  • Line voltage outside motor operating range (too high or too low)
  • Motor internal over-temperature condition
  • Bearing or load condition causing overheating

Next checks to confirm
  1. Measure line voltage at furnace and compare to motor nameplate operating range
  2. Check blower motor amp draw and compare to nameplate
  3. Inspect blower wheel for obstruction or bearing issues
  4. Verify motor cooling path is not obstructed

Escalation
Blower motor trips; furnace fails to operate until voltage/temperature condition is corrected
Reset behavior
Clears after voltage/temperature condition returns to normal.
Urgent
Fix now
Source
DC96VC/DM96VC Service Instructions status code page; public furnace status-code reference