Fault Code Lookup

HVAC Sales Master
88-75
PFCM Sensor B lockout
This code typically points to
  • Internal PFC current-sensing failure/excess in VFD

Next checks to confirm
  1. Manual power cycle
  2. Replace VFD if persists

Escalation
4-hour lockout.
Reset behavior
4-hour lockout.
Urgent
Fix now
Need deeper detail?
Retrieve the subcode for this platform:
  1. From the main screen, touch Menu
  2. Touch and hold the Service icon for at least 10 seconds until it turns green
  3. Open Service Information
  4. Use View Diagnostics for the most recent fault's top three likely root causes
  5. Use Last 10 System Events for timestamped recent events
  6. Use Run/Fault History for resettable fault counters, cycle counters, and run times
Source
186CNV/284ANV service manual