62-01
PEV solenoid open
This code typically points to
  • PEV solenoid coil failure
  • Broken wire to solenoid
  • Connection fault

Next checks to confirm
  1. Verify voltage to PEV solenoid
  2. Measure solenoid coil resistance
  3. Inspect wiring

Escalation
Replace PEV solenoid after confirming wiring and voltage.
Reset behavior
Clears when solenoid circuit restored.
Service Soon
Schedule repair
Need deeper detail?
Retrieve the subcode for this platform:
  1. From the main screen, touch Menu
  2. Touch and hold the Service icon for at least 10 seconds until it turns green
  3. Open Service Information
  4. Use View Diagnostics for the most recent fault's top three likely root causes
  5. Use Last 10 System Events for timestamped recent events
  6. Use Run/Fault History for resettable fault counters, cycle counters, and run times
Source
Carrier inverter service manual