52-02
Outdoor coil temperature (OCT) sensor shorted
This code typically points to
  • Failed OCT thermistor
  • Short in sensor wiring

Next checks to confirm
  1. Measure OCT sensor resistance
  2. Inspect wiring for shorts

Escalation
Replace sensor after wiring confirmed good.
Reset behavior
Clears when sensor reading returns to valid range.
Service Soon
Schedule repair
Need deeper detail?
Retrieve the subcode for this platform:
  1. From the main screen, touch Menu
  2. Touch and hold the Service icon for at least 10 seconds until it turns green
  3. Open Service Information
  4. Use View Diagnostics for the most recent fault's top three likely root causes
  5. Use Last 10 System Events for timestamped recent events
  6. Use Run/Fault History for resettable fault counters, cycle counters, and run times
Source
Carrier inverter/Connex service manual event tables