52-01
Outdoor coil temperature (OCT) sensor open
This code typically points to
  • Failed OCT thermistor
  • Broken sensor wire
  • Connection fault

Next checks to confirm
  1. Measure OCT sensor resistance
  2. Verify wiring continuity to board

Escalation
Replace sensor after wiring confirmed good.
Reset behavior
Clears when sensor reading returns to valid range.
Service Soon
Schedule repair
Need deeper detail?
Retrieve the subcode for this platform:
  1. From the main screen, touch Menu
  2. Touch and hold the Service icon for at least 10 seconds until it turns green
  3. Open Service Information
  4. Use View Diagnostics for the most recent fault's top three likely root causes
  5. Use Last 10 System Events for timestamped recent events
  6. Use Run/Fault History for resettable fault counters, cycle counters, and run times