HEARTBEAT (component-test post-indication)
Post-component-test indication: no errors detected. Visual check of hot surface igniter, inducer, and blower motor required.
This code typically points to
  • Normal post-component-test result when no setup error is present and visual component sequence completes

Next checks to confirm
  1. Run component test with R disconnected and SW1-6 ON
  2. Observe inducer high-speed, igniter ON, blower ON, then inducer low-speed
  3. If heartbeat is post-test indication, verify visually that those components actually operated

Escalation
No escalation if observed sequence matches OEM component-test sequence. Escalate only if heartbeat appears but a component visibly failed to operate.
Reset behavior
After testing, put SW1-6 in OFF position and reconnect R thermostat lead.
Informational
No action needed
Source
ICP (F/G)9MVE A3/A4 Service Manual Component Self-Test section and Figure 15 Service Label component-test box