1+2
Blower on after power up (115VAC or 24VAC). Blower runs 90 seconds if unit powered up during call for heat, or when R-W/W1 opens during blower on-delay period.
This code typically points to
  • Not a fault; typical triggers are power restoration during active heat call, or loss/opening of heat call during blower on-delay period

Next checks to confirm
  1. Verify whether power was just restored during heat call, or whether R-W/W1 opened during blower on-delay
  2. If yes, treat as normal 90-second blower-only operation

Escalation
No escalation if behavior matches OEM conditions and clears after 90-second interval.
Reset behavior
Self-clearing. After 90-second period, LED returns to heartbeat if no faults detected.
Informational
No action needed
Source
ICP Service and Technical Support Manual, Gas Furnace: (F/G)9MVE A3/A4, Figure 15 Service Label and Figure 17 / Sequence of Operation